Download Print this page

Types And Roles Of Monitor Data - Mitsubishi Electric AJ65BT-D75P2-S3 User Manual

Hide thumbs Also See for AJ65BT-D75P2-S3:

Advertisement

5 DATA USED FOR POSITIONING CONTROL

5.1.7 Types and roles of monitor data

Monitor the module name
Monitor the OS type
Monitor the OS version
Monitor the clock data used in the system
Data that indicates the positioning system's operation state is stored in the buffer
memory's monitor data area remote registor (RWr).
When using the positioning system, this data must be monitored as necessary.
The data that can be monitored is shown below.
Monitoring the system
Monitors the D75P2 specifications, such as the module name and OS type, and the
operation history. (System monitor data Md.1 to Md.28 )
Monitoring the axis operation state
Monitors the data related to the operating axis, such as the current position and
speed. (Axis monitor data Md.29 to Md.56 )
However, Md.29 , Md.31 to Md.35 , Md.39 , Md.40 , Md.49 and Md.50 must
not be used.
* The axis monitor data is updated every 56.8ms.
(1) Monitoring the system
Monitoring the D75P2 specifications
Monitor details
Md.2
Module name
Md.3
OS type
Md.4
OS version
Md.5
Clock data (Hour: minute)
Md.6
Clock data (Second: 100ms)
5 - 11
MELSEC-A
Corresponding item

Advertisement

loading