4 INSTALLATION, WIRING AND MAINTENANCE OF THE PRODUCT
7)
External device connection connectors (AX1, AX2)
Connectors for connection of the drive unit, mechanical system input and manual
pulse generator.
8)
17-segment LED
Display the message that indicates the operation status according to the mode.
9)
Peripheral device connection connector
Connector for connection with the peripheral device.
10)
Terminal block
Terminals for connection with the master module.
11)
Maker maintenance connector
Connector for writing D75P2 programs.
*This connector is used by the maker only. Do not open the cover.