12 CONTROL AUXILIARY FUNCTIONS
Setting item
Command in-
Pr.17
position width
* Refer to section "5.2 List of parameters" for setting details.
Monitor item
Command in-position
signal
* Refer to section "3.4 Specifications of input/output signals for master module" for information on the storage
details.
(3) Setting the command in-position function
To use the "command in-position function", set the required value in the
parameter shown in the following table, and write it to the D75P2.
The set details are validated at the rising edge (OFF
READY signal [RX(n+7)B].
Setting
value
Turn ON the command in-position signal, and set the
remaining distance to the stop position of the position
control.
(4) Confirming the command in-position signal
The "command in-position signal" is stored in the following remote input/output.
Monitor
value
OFF: Outside in-position range
ON: Within in-position range
REMARK
Parameters are set for each axis.
Setting details
Storage details
12 - 71
MELSEC-A
ON) of the remote station
Factory-set
initial value
100
Remote input/output
Axis 1
Axis 2
RX(n+1)E RX(n+4)E