5 DATA USED FOR POSITIONING CONTROL

5.1.5 Setting items for start block data

Advanced positioning
Start block data
setting items
Shape
Da.10
Start data No.
Da.11
Special start command
Da.12
Parameter
Da.13
: Set as required ("–" when not set)
– : Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the
setting range, there is no problem.)
The "start block data" must be set when carrying out "advanced positioning control".
The setting items for the "start block data" are shown below.
Up to 50 points of "start block data" can be set for each axis.
Refer to "Chapter 10 ADVANCED POSITIONING CONTROL" for details on the
"advanced positioning control", and to section "5.4 List of start block data" for details on
each setting item.
Block start
control
Condition
(Normal
start
start)
Checking the start block data
Da.10 to Da.13 are checked with the following timing.
(1) When the "Start block data" starts
(2) When the test mode using the AD75 software package
Simulta-
Wait start
neous start
5 - 9
MELSEC-A
Repeated
Repeated
Stop
start
(FOR
(FOR loop)
condition)
start