5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.32 Interrupt request during
continuous operation
Cd.33 New acceleration time value
Cd.34 New deceleration time value
Cd.35 Acceleration/deceleration
time change during speed
change, enable/disable
selection
Cd.36 Speed/position changeover
control (ABS mode) function
valid flag
To interrupt the operation during continuous operation, set "1".
(In the non-operation mode (when the BUSY signal [RXn4, RXn5] is OFF), the
interrupt request during continuous operation is not accepted.)
Cleared to 0 at a start or at a restart.
If the interrupt request is received after setting "1", "0" will be automatically stored
by the OS.
When changing the acceleration time during speed change, set the new
acceleration time.
Pr.25
setting
1-word type
2-word type
When changing the deceleration time during speed change, set the new
deceleration time.
Pr.25
setting
1-word type
2-word type
Set whether to enable/disable the acceleration/deceleration time change during
speed change.
Set the INC mode or ABS mode of speed/position changeover control.
5 - 110
Setting details
Cd.33
setting range (unit)
0 to 65535 (mm)
0 to 8388608 (ms)
Cd.33
setting range (unit)
0 to 65535 (mm)
0 to 8388608 (ms)
MELSEC-A