14
TROUBLESHOOTING
Relevant buffer memory address
remote input/output device, or remote
register
Axis 1
Axis 2
RWwm+1
RWwm+9
1176
1226
24
174
Refer to section "5.3 List of positioning
data" for the command speed.
Bias speed at start
12, 13
162, 163
5102
RY(n+2)7
RY(n+4)7
New speed value
RWwm+4
RWwm+12
RWwm+5
RWwm+13
JOG speed limit value
48, 49
198, 199
1168
1218
1169
1219
Manual pulse generator
enable flag
RY(n+2)9
RY(n+4)9
Manual pulse generator selection
29
179
Setting range
<Positioning operation speed override>
1 to 300
<New torque value>
1 to [torque limit setting value]
<Torque limit setting>
1 to 500
<Command speed, bias speed at start>
<In standard mode>
0 to 1000000 [pulse/s]
0 to 600000000 [mm/min, etc.]
<In stepping motor mode>
0 to 62500 [pulse/s]
0 to 37500000 [mm/min, etc.]
<No. of read/write data>
1 to 100
<Speed change request>
ON: Speed change request
<New speed value or JOG speed limit
value>
<In standard mode>
0 to 1000000 [pulse/s]
0 to 600000000 [mm/min, etc.]
<In stepping motor mode>
0 to 62500 [pulse/s]
0 to 37500000 [mm/min, etc.]
[In case of speed change value, the
minimum setting is "0."]
<Manual pulse generator 1 pulse input
magnification>
1 to 100
<Manual pulse generator enable flag>
OFF: Operation using the manual pulse
generator is not enabled.
ON : Operation using the manual pulse
generator is enabled.
<Manual pulse generator selection>
0: Manual pulse generator operation
ignored
1: Manual pulse generator connected to
axis 1 is used.
2: Manual pulse generator connected to
axis 2 is used.
14 - 37
Remedy
Set a value within the setting range.
Change the command speed and bias speed at start so
that the command speed is equal to or larger than the
bias speed at start.
Change the setting to within the setting range and issue
a read/write request. (Refer to section 7.2)
Do not change the JOG speed during deceleration
caused by turned OFF of the JOG start signal.
Change the setting to within the setting range.
Change the manual pulse generator 1 pulse input
magnification to within the setting range.
 Change the manual pulse generator enable flag to
prohibition.
 Change the manual pulse generator selection setting
to a value between 1, 2.
MELSEC-A