12 CONTROL AUXILIARY FUNCTIONS
Setting item
Positioning start No.
* For the setting details, refer to section "3.5 Remote registers".
Signal name
Remote station READY
signal
D75P2 READY signal
Axis stop signal
Interface
signal
Start complete signal
BUSY signal
Error detection signal
M code ON signal
Drive unit READY signal
Stop signal
External
signal
Upper limit (FLS)
Lower limit (RLS)
(a) Data that requires setting
The following data must be set to execute the indirectly specification
function.
Setting value
Set "8001" that indicates the control using
8001
the "indirectly specification data".
(b) Starting conditions
The following conditions must be satisfied to make a start. Also, the
required conditions must be incorporated into the sequence program, and
the data must be disabled from starting if the conditions are not satisfied.
ON
Positioning operation possible
OFF
D75P2 preparation completed
OFF
Axis stop signal is OFF
OFF
Start complete signal is OFF
OFF
BUSY signal is OFF
OFF
There is no error
OFF
M code ON signal is OFF
Drive unit preparation completed
ON
OFF
Stop signal is OFF
Within limit range
ON
Within limit range
ON
12 - 81
Setting details
Signal state
MELSEC-A
Remote register
Axis 1
Axis 2
RWwm
RWwm+8
Device
Axis 1
Axis 2
RX(n+7)B
RXn0
RY(n+1)3
RY(n+1)4
RXn1
RXn2
RXn4
RXn5
RXnA
RXnB
RXnD
RXnE
RX(n+1)2
RX(n+4)2
RX(n+1)6
RX(n+4)6
RX(n+1)7
RX(n+4)7
RX(n+1)8
RX(n+4)8