5 DATA USED FOR POSITIONING CONTROL
Da.13 Parameter
Set the value as required for " Da.12 Special start command".
Da.12 Special start command
Block start (Normal start)
Condition start
Wait start
Simultaneous start
Stop
Repeated start (FOR loop)
Repeated start (FOR condition)
Setting value
Not used. (There is no need to set.)
Set the condition data No. (No. of
"condition data" set to perform
condition judgement)
1 to 10
(For details of the condition data, refer
to Section 5.5.)
Not used. (There is no need to set.)
0 to 255
Set the No. of repetitions.
Set the condition data No. (No. of
"condition data" set to perform
1 to 10
condition judgement)
(For details of the condition data, refer
to Section 5.5.)
5 - 74
MELSEC-A
Setting details