Download Print this page

Operation Patterns Of Main Positioning Controls - Mitsubishi Electric AJ65BT-D75P2-S3 User Manual

Hide thumbs Also See for AJ65BT-D75P2-S3:

Advertisement

9 MAIN POSITIONING CONTROL

9.1.2 Operation patterns of main positioning controls

< Operation example when "1-axis linear positioning" is set in the positioning data of axis 1 >
Positioning data No.1
No.2
No.3
No.4
No.5
No.6
Speed
Da. 1 Operation pattern
b
11
a
NO.1
0
A
(Positioning data)
(One motor is driven, and positioning is carried out to an addresses designated in one direction.)
In "main positioning control" (advanced positioning control), " Da.1 Operation
pattern" can be set to designate whether to continue executing positioning data after
the started positioning data. The "operation pattern" includes the following 3 types.
·
Positioning complete
·
Positioning continue
The following shows examples of operation patterns when "1-axis linear control (ABS
linear 1)" is set in positioning data No. 1 to No. 6 of axis 1. Details of each operation
pattern are shown on the following pages.
(Setting details)
Positioning to address [A] at command speed [a]
Positioning to address [B] at command speed [b]
Positioning to address [C] at command speed [a]
Positioning to address [D] at command speed [b]
Positioning to address [E] at command speed [a]
Positioning to address [F] at command speed [a]
11
01
Speed is changed
without stopping
No.2
No.3
B
C
For
1-axis linear control
POINT
When position control of movement amount 0 is executed, the BUSY signal [RXn4,
RXn5] also turns ON. However, since the ON time is short, the ON status may not
be detected in the sequence program.
(1) Independent positioning control
(operation pattern: 00)
(2) Continuous positioning control
(operation pattern: 01)
(3) Continuous path control
(operation pattern: 11)
Operation pattern = 11: Continuous path control
Operation pattern = 11: Continuous path control
Operation pattern = 01:
Operation pattern = 01:
Operation pattern = 00: Independent positioning control
Operation pattern = 11: Continuous path control
01
The machine stops, and
then continues the next
positioning operation.
No.4
D
(Direction in which axis 1 addresses increase)
9 - 4
MELSEC-A
Continuous positioning control
Continuous positioning control
(Positioning complete)
00
Positioning is terminated
No.5
Address
E
F
No.1 Start
Control stop
Time

Advertisement