JVL MAC050 User Manual page 97

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

4.2
Expansion Modules MAC00-B1/B2/B4
4.2.17
MAC00-B4 dip-switch setup
The 6 pole dip-switch is placed on the rear side of the MAC00-B4 module. The following
illustration shows how to set up the switch.
Input type setup
Dip 5 - RS232 TxPD
Dip 6 - RS485 Term.
Default switch setting:
As shown above. Dip1-6=OFF,ON,OFF ,ON,ON,OFF
- Input A and B is setup for PNP outputs.
- RS232 TxPD (Transmit pull-down) is enabled.
- RS485 Termination is disabled.
Input type setup (only switch 1-4)
Balanced or "push-pull" output connected
to the A and B input
1
2
3
4
5
6
SW1
RS232 TxPD setup (only switch 5)
One of the motors connected to an RS232 line must have this switch set to "ON" but only at one !.
1
2
3
4
5
6
SW1
RS485 Term. setup (only switch 6)
The last motors connected to an RS485 line must have this switch set to "ON" but only at one !.
1
2
3
4
5
6
SW1
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Mini dip-switch
OFF
1
Dip-Switch for
2
3
4
5
6
SW1
OFF
NPN (sink) output connected to the A and B input
OFF
OFF
OFF
1
ON
-
OFF
2
-
3
ON
OFF
4
-
5
-
6
SW1
-
-
-
-
ON/OFF
-
-
-
-
-
-
ON/OFF
MAC00-B4 Dip switch settings
Rear side of the MAC00-B4
expansion module
ON
PNP (source) output connected to the A and B input
1
OFF
2
ON
OFF
3
4
ON
-
5
-
6
SW1
Main fuse 10Amp.
Replace only with:
Schurter type
"3402.0040.11"
or
Littlefuse type
"451-10A"
TT1031GB