4.3
Expansion module MAC00-B41
4.3.7
RS232 - General description when using the MAC00-B41 module
The RS232 interface is consid-
ered the main interface to the
motor when the motor is set
up using the MacTalk win-
dows software from a PC or
from any kind of controller us-
ing a RS232 interface.
Note:The basic MAC motor
does not fully support RS232
since the interface signals are
only 5V levels. See also the ba-
sic description - Serial interface,
page 69.
When connecting the RS232
interface to a PC or control-
ler, the following rules must
be followed:
1 Only one motor can be
connected at the interface
line. Use the RS485 if multi-
ple units have to be con-
nected at the same time.
2 Use screened cable.
3 Ensure that GND is also
connected.
4 Ensure that all units have a proper connection to safety ground (earth) in order to refer
to the same potential.
5 The RS232 interface cable length should not exceed 10 metres.
Connectors:
To see the specific connector pin-out please see the chapter Expansion MAC00-B41 con-
nector description, page 105.
A finished RS232 cable also exist. Please see Cables for the MAC00-B41, page 107
100
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
RS232 connection between a PC or central controller
to MAC400 with a MAC00-B41 module.
Central
Make sure that all
involved units are
Controller
connected to the same
(for example a PC)
potential
Opto isolation *
Screen connected
to GND in each end
MAC400 Motor
with MAC00-B41
Rx
Tx
GND
Contr. Voltage CVI
* Opto isolation is recommended if connection is permanent.
Only MAC400&800
Power supply
RS232
Interface
Max. 32VDC !
P+
Power
Supply
P-
Mains 230VAC
Main supply
TT1143GB