JVL MAC050 User Manual page 92

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

4.2
Expansion Modules MAC00-B1/B2/B4
4.2.12
General description MAC00-B1
The MAC00-B1 expansion module is an industrial interface that mates with the standard
MAC motor and offers a number of feature enhancements, including:
• Standard 9-pin D-SUB connectors for additional reliability.
• Addition of a Zero switch input for locating a mechanical zero point of the actuator
when used in position-related modes.
• Plugable screw terminal connector for power supply and Zero switch.
• LEDs to indicate: O1 and O2 output status, Zero switch (analogue input) status.
Input power status.
• Full RS232 and RS485 protocol support for use with standard 9-pin DSUB.
• Sourcing (PNP) outputs for status signals O1 and O2 instead of sinking (NPN).
The following illustration shows all the connectors on the MAC00-B1 module.
88
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
MAC00-B1 connector descriptions
General I/O
Signal ground
Balanced pulse in- or outputs used for
Pulse and direction signals or
Quadrature encoder signal
Optional these terminals can be
used for the MAC high speed
communication using RS422
RS232 Connections
S E T U P
RS485 Connections
1
2
RS232 Rx
3
RS232 TX
4
RS485 A-
5
Signal ground
(for RS232 and RS485
RS232 Interface between MAC motor and a PC.
MAC00-B1
PC
Gnd
Gnd
5
Tx
Tx
3
7
2
Rx
Rx
1
Use JVL programming cable type RS232-9-1
for connecting to PC.
IN /O U T
5
GND
9
4
B-
8
3
B+
7
2
A-
6
1
A+
Industri Elektronik
IN / O U T
S E T U P
O 1
O 2
M A C 0 0 -B 1
O ption
RS232 Note !
The TX-PD terminal must
be connected to Tx (pin 3)
if the MAC motor is not
6
using addressing
7
Tx-PD
Notes :
8
Terminator
9
*
RS485 B+
**
5
3
7
2
1
Status outputs
O+
Default:
O2
O1 = In position output
O2 = Error output
O1
Analogue input +/-10V.
AIN
Optional zero sensor input
LED's for showing the output status of
O1 and O2. Notice that LED's are only
active if the O+ terminal is supplied.
LED for showing the voltage level at
the analogue input (AIN).
LED for showing the voltage level at
the power supply input (P+)..
Power/Analogue input
P+
(Main power +12-48(32)VDC *)
AIN
(Analog input / zero switch input **)
P-
(Power ground - also for AIN)
MAC50-141:
P+ is main supply terminal
Apply +12-48VDC.
MAC800:
P+ is the control supply terminal
Apply +12-32VDC (max 32V!)
Do not apply higher voltages
than 32VDC to the AIN terminal.