JVL MAC050 User Manual page 272

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

5.7
Emergency stop considerations
DS/EN ISO 13849-1 utilizes another criterion for safety level called the "Performance
level" - PL – in which both the architecture and the component's failure rate are included.
5 PL levels are defined: a, b, c, d, and e, where a represents the lowest level and e the
highest.
If DS/EN ISO 13849-1 is used, information regarding the components' failure rates
(MTTF – mean time to failure) must be obtained from the component manufacturer.
For a more detailed description of the principles and requirements above, see the rele-
vant standards.
The following drawings illustrates examples of the design of safety circuits for an emer-
gency stop and enclosure system, stop category 0, which fulfils the requirements of
category 4 in accordance with DS/EN 954-1.
The achievable PL level in accordance with DS/EN ISO 13849 will depend on the MTTF
of the components used; using the solutions shown, typically a minimum PL level d would
be achieved.
268
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800