4.4
Expansion Modules MAC00-FC2/FC4
4.4.24
Object 2011h – Subindex 1 Input status
This object is used to read out the actual value of the inputs.
Bit
Input
PL is the positive limit switch input, and NL is the negative limit switch input. IN1-IN4 is
the digital user inputs. On the MAC00-FC2 module are the input connected via J2, and
on the MAC00-FC4 module are the input connected via the M12 connectors marked
I/O.
4.4.25
Object 2011h – Subindex 2 Outputs
With this object the outputs can be controlled.
The value written to this object is directly shown on the outputs if the outputs are not
set to use the default function (see subindex 5).
Bit
Output
01 and 02 are the digital user output 1 and 2. On the MAC00-FC2 module the outputs
are connected via J4, and on the MAC00-FC4 module the outputs are connected via the
M12 connectors marked I/O.
4.4.26
Object 2011h – Subindex 3 Motor status
With this object the status of the motor can be monitored.
Bit
Data
Bit 6: Equals 1, if the velocity is decreasing.
Bit 5: Equals 1, if the velocity is increasing.
Bit 4: Equals 1, if the motor is at the commanded position.
Bit 2: Equals 1, if a limit switch has been activated.
Bit 1: Equals 1, if there is a communication error between the MAC00-FC and the
motor. This could occur if the motor has been reset due to a voltage drop.
Bit 0: Equals 1, if there is a fatal motor error. Read subindex 4 to get extended informa-
tion.
136
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
7
6
Reserved
PL
7
6
7
6
Decele-
Accele-
Reserved
ration
ration
5
4
3
NL
IN4
5
4
3
Reserved
5
4
3
In position Reserved
2
1
0
IN3
IN2
IN1
2
1
0
O2
O1
2
1
0
Limit
Discon-
Motor
switch
nected
Error
Error