4.8
Expansion module MAC00-P5
4.8.6
RS232 - General description when using the MAC00-P5 module
The RS232 interface is consid-
ered the main interface to the
motor when the motor is set
up using the MacTalk win-
dows software from a PC or
from any kind of controller us-
ing a RS232 interface.
Note:The basic MAC motor
does not fully support RS232
since the interface signals are
only 5V levels. See also the ba-
sic description - Serial interface,
page 69.
When connecting the RS232
interface to a PC or control-
ler, the following rules must
be followed:
1 Only one motor can be
connected at the interface
line. Use the RS485 if multi-
ple units have to be con-
nected at the same time.
2 Use screened cable.
3 Ensure that GND is also
connected.
4 Ensure that all units have a proper connection to safety ground (earth) in order to refer
to the same potential.
5 The RS232 interface cable length should not exceed 10 metres.
Connectors:
To see the specific connector pin-out please see the chapter Expansion MAC00-B41 con-
nector description, page 105.
A finished RS232 cable also exist. Please see Cables for the MAC00-B41, page 107
208
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
RS232 connection between a PC or central controller
to MAC400 with a MAC00-Px module.
Central
Make sure that all
involved units are
Controller
connected to the same
(for example a PC)
potential
Opto isolation *
Screen connected
to GND in each end
MAC400 Motor
with MAC00-Px
Rx
Tx
IGND
Contr. Voltage CVI1
TT1167GB
Main supply
* Opto isolation is recommended if the Rs232 connection is a permanent installation.
Only MAC400&800
Power supply
The terminal P+
do not exist on
MAC00-P5.
Use only CVI1
RS232
Interface
Max. 32VDC !
P+
Power
Supply
P-
Mains 115/230VAC