4.9
Expansion Module MAC00-R1/R3/R4
4.9.10.15 Wait for an input combination before continuing (multiple inputs)
Icon:
Dialogue:
Function:
234
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Waits for a specified input condition to occur. The next line in the program
will not be executed until the input condition has been met. If "Input type"
is set to "Multiple", multiple inputs can be tested for being either high or
low.
The "Operand" setting determines whether one or all of the inputs must
meet their test criterion. If set to "And" all inputs must match their test
settings. If set to "Or" only one input need to match its test setting. Inputs
that are set to "Don't care" are not tested. The inputs are tested with
30 microsecond intervals.