4.9
Expansion Module MAC00-R1/R3/R4
4.9.10.14 Wait for an input combination before continuing (single input)
Icon:
Dialogue:
Function:
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Waits for a specified input condition to occur. The next line in the program
will not be executed until the input condition has been met. If "Input type"
is set to "Single", the command will wait for one of four things to happen
on the specified input: that the input tests as high, that the input tests as
low, that the input transitions from high to low (Falling Edge). The input is
tested with 30 microsecond intervals.