Serial Interface - JVL MAC050 User Manual

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

3.3
3.3.1
Interface Connection
The Controller Interface is based on an asynchronous serial interface.
3 interface signals, Rx, Tx and ground are used. The interface can be used directly with
the serial COM port of any standard PC or PLC by using the optional cable type RS232-
9-1-MAC which has an integrated RS232 converter. Another possibility is to use one of
the expansion modules for the MAC motor which also include an RS232 and RS485 con-
verter. See also Accessories, page 291.
3.3.2
RS232 Interface signal levels
Please note that the signal levels are 0 to +5V(3.3V)DC and are thus not according to
the RS232 standard which requires +/-12V nominal at the RX and TX signals. However
the protocol used is equivalent to the RS232 protocol.
If the Basic MAC motor is implemented in an OEM application where an internal proc-
essor communicates with the MAC motor, the TX and RX terminals can normally inter-
face directly.
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800

Serial interface

Asynchronous
Serial Interface
Connector located inside the Basic MAC motor
4 - Ground
3 - Transmit Tx (5V level)*
2 - Receive Rx (5V level)
1 - +5VDC out (max. 30mA)
Connector cable part:
Manufacturer : JST
Type : ZHR-4 (1.5mm pitch)
Crimp contacts : SZH-002T-P0.5
* MAC400 and 800 uses 3.3V as Tx level
TT0912GB
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mac800Mac141Mac400

Table of Contents