4.9
Expansion Module MAC00-R1/R3/R4
4.9.10.13 Wait for (x) ms before continuing
Icon:
Dialogue:
Function:
232
JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 800
Causes the program to pause for a number of milliseconds, before
continuing. The longest pause that can be specified is 65535 milli-
seconds. The shortest pause that can be specified is 0 milliseconds.
Note that this command over writes Timer 1 in the RxP modules memory.