Plc Side Setting - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

12.2.5

PLC Side Setting

PLC CPU
■1. Connecting to T2 (PU224), T2E or T2N
(1) Switch setting
Set the switches accordingly.
(a)
Operation mode setting switch
(b)
DIP switch on module PCB (T2N only)
DIP switch: No. 1
*1
(2) Transmission parameter setting
Enter the transmission parameters.
Transmission speed
Data bit
Stop bit
Parity bit
Station No.
*1
*2
*3
12 - 10
12.2 Serial Connection
POINT
POINT
POINT
TOSHIBA PLC
For details of the TOSHIBA PLC, refer to the following manual.
TOSHIBA PLC user's Manual
Model name
T2 (PU224), T2E, T2N
T3, T3H
model 2000 (S2, S2T, S2E), model 3000 (S3)
Switch No.
4
5
Switch No.
Can be used as RS-422.
Item
*1*2*3
Indicates only the transmission speeds that can be set on the GOT side.
Fixed to 9600bps for T2E only.
The transmission speed setting must be consistent with that of the GOT side.
For the transmission speed setting on the GOT side, refer to the following.
➠ ■1.
Setting communication interface (Communication settings)
OFF ON
1
2
3
4
5
6
Settings
OFF (fixed)
OFF (fixed)
For RS-232 communication
ON (RS-232C)
4800bps, 9600bps, 19200bps
7bit
2bit
Even
1
Refer to
12 - 10
12 - 11
12 - 11
Setting details
Computer link
Set value
For RS-422 communication
OFF (RS-485
Set value
*1
)