Advertisement

2.5.5
Station No.settings
Set each station number so that no station number overlaps.
The station number can be set without regard to the cable connection order. There is no problem even if station numbers
are not consecutive.
■1. Direct specification
When setting the device, specify the station number of the controller of which data is to be changed.
PCON, ACON, SCON
ERC2
■2. Indirect specification
When setting the device, indirectly specify the station number of the controller of which data is to be changed using the
16-bit GOT internal data register (GD10 to GD25).
When specifying the station No. from 100 to 115 on GT
Designer3, the value of GD10 to GD25 compatible to the station No. specification will be the station No. of the
controller.
Specification station No.
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
2 - 32
2.5 Robot Controller Side Setting
Station
Station
No.3
No.7
GOT
Examples of station number setting
Model name
Compatible device
GD10
GD11
GD12
GD13
GD14
GD15
GD16
GD17
GD18
GD19
GD20
GD21
GD22
GD23
GD24
GD25
Station
Station
Station
No.1
No.15
No.6
Specification range
0 to 15
0 to 15
Setting range
0 to 15
(If setting a value out of the range above, a timeout error occurs.)
Refer to
2.5.3
2.5.4