2Coaxial Cableconnector Connection Method - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

1.4.2
Coaxial cableconnector connection method
The following describes the method for connecting the BNC connector (connector plug for coaxial cable) and the cable.
Solder the coaxial cable connectors properly.
Insufficient soldering may result in malfunctions.
Components of the BNC connector
Plug shell
Step 1.
Remove the external sheath of the coaxial cable with dimensions as shown below.
Cut this portion of the outer sheath
3C-2V
5C-2V, 5C-2V-CCY
Step 2.
Pass the nut, washer, gasket, and clamp through the coaxial cable as shown on the left and loosen the
external conductor.
Step 3.
Cut the external conductor, insulting material, and internal conductor with the dimensions as shown below.
Note that the external conductor should be cut to the same dimension as the tapered section of the clamp
and smoothed down to the clamp.
Internal conductor
3C-2V
5C-2V, 5C-2V-CCY
CAUTION
Nut
Washer
Gasket
Clamp
Contact
A
Cable in use
Clamp
Nut
Washer
Gasket
Insulating material
C
B
Clamp and external
conductor
Cable in use
1.4 Connection Cables for the Respective Connection
Structure of the coaxial cable
External conductor
Outer sheath
Insulating material
Internal conductor
B
6 mm
7 mm
1
A
15 mm
10 mm
C
3 mm
5 mm
1 - 29