Step 4.
Solder the contact to the internal conductor.
Step 5.
Insert the connector assembly shown in ### into the plug shell and screw the nut into the plug shell.
Precautions for soldering
Note the following precautions when soldering the internal conductor and contact.
• Make sure that the solder does not bead up at the soldered section.
• Make sure there are no gaps between the connector and cable insulator or they do not cut into each other.
• Perform soldering quickly so the insulation material does not become deformed.
1 - 30
1.4 Connection Cables for the Respective Connection
Solder here