Plc Side Setting - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

6.2.8

PLC Side Setting

PLC CPU
Multi-communication unit
■1. Connecting KV-7300, KV-3000, KV-1000
Setting items
Transmission Speed
Data bit
Parity bit
Stop bit
*1
■2. Connecting to KV-700
Setting items
Transmission Speed
Data bit
Parity bit
Stop bit
■3. Connecting to KV-L20R, KV-L20, KV-L20V, KV-L21V
(1) Communication settings
Setting items
Communication mode
*1*2
Transmission speed
Data bit
Parity bit
Stop bit
*3
Station No.
*1
*2
*3
6 - 24
6.2 Serial Connection
POINT
POINT
POINT
KEYENCE PLC
For details of KEYENCE PLC, refer to the following manual.
KEYENCE PLC user's Manual
Model name
There is no transmission speed setting on the PLC side.The transmission speed of the PLC side is automatically adjusted to that
of the GOT side.
Only transmission speeds available on the GOT side are shown.
The transmission speed setting must be consistent with that of the GOT side.
For the transmission speed setting on the GOT side, refer to the following.
Setting communication interface (Communication settings)
Set the station No. according to the host address on the GOT side.
For the Host Address setting on the GOT side, refer to the following.
Setting communication interface (Communication settings)
KV-7300
KV-3000
KV-1000
KV-700
KV-L20R
KV-L20
KV-L20V
KV-L21V
*1
9600 to 115200 bps
8bits
Even
1bit
9600bps
8bits
Even
1bit
KV mode (Upper link)
4800bps, 9600bps, 19200bps, 38400bps, 57600bps, 115200bps
8bits
Even
1bit
0 to 9
Reference
6 - 24
6 - 24
6 - 24
6 - 24
6 - 24
Set value
Set value
Set value