6-1-14 I/O Axis - Omron CS1W-MCH71 Operation Manual

Sysmac cs/cj-series
Hide thumbs Also See for CS1W-MCH71:
Table of Contents

Advertisement

Basic Information
Function item
Establishing machine
coordinate system origin
Present value monitor
Error on the communica-
tion path (Synchronous
communication error,
etc.)

6-1-14 I/O Axis

Function item
Axis control bits
Axis status bits
Present value monitor
The position where power is turned ON is determined as machine coordinate system origin.
(Operates in [Origin at power ON] mode.)
It is possible to determine a user-specified position as an origin using the axis control bit
[Forced origin].
Present coordinate system FB position
Machine coordinate system FB position
Present coordinate system command posi-
tion
Machine coordinate system command posi-
tion
Counter latch position
Feedback speed 1
Feedback speed 2
Command speed 1
Command speed 2
Error
Torque command value
Workpiece origin shift amount
Origin margin
No. of multi-turns
MECHATROLINK servo status
Absolute position setting value
Does not occur.
The following table describes the differences between axes allocated as I/O
and as servo.
All disabled except for "bit 00: Axis alarm reset."
bit
Name
00
Axis alarm
01
Machine origin
02
Busy
03
Servo lock
04
No origin
05
Axis started
06
Positioning completed
07
Positioning completed (No.2)
08
Error counter warning
09
Axis machine lock status
10
Counter latch completed
11
M-10 Warning
12
Reserved
13
Command disabled/enabled
14
Axis not used/used
15
In manual/automatic mode
Always 0
Specifications
= Present coordinate system command position
= Machine coordinate system command posi-
tion
Same as for the real axis
Same as for the real axis
Always 0
= Command speed 1
Always 0
Same as for the real axis
Always 0
Always 0
Always 0
Same as for the real axis
Always 0
Same as for the real axis
Always 0
Always 0
Specifications
ON/OFF status
As usual, turns ON/OFF.
Always OFF.
Always OFF.
Always OFF.
Always OFF.
Always OFF.
Always OFF.
Always OFF.
Always OFF.
Always OFF.
Always OFF.
Intelligent I/O turns ON/OFF, as usual.
Always OFF.
As usual, turns ON/OFF.
Always OFF.
Always OFF.
Section 6-1
283