System Parameters
No.
Address in MC
Unit
P2AA09
55C8h +
(AA * 14h)
Data configuration
31
S-curve filter enabled
Note
No.
Address in MC
Unit
P2AA10
55C9h +
(AA * 14h)
Data configuration
31
S-curve filter enabled
Note
No.
Address in MC
Unit
P2AA11
55CAh +
(AA * 14h)
Data configuration
31
S-curve time constant
Note
No.
Address in MC
Unit
P2AA12
55CBh +
(AA * 14h)
Data configuration
31
S-curve time constant
88
Name
Rapid feed S-curve filter enabled
Setting range
00000000 to 00000001 Hex
00
(0 to 1)
Explanation
Selects the S-curve filter enable/disable at rapid feed rate.
0: Disabled
1: Enabled
For details of Accel/decel patterns, see 6-1-5 Axis Movement Operation (Page
248).
Name
Manual feed S-curve filter enabled Data
Setting range
00000000 to 00000001 Hex
00
(0 to 1)
Explanation
Selects the S-curve filter enable/disable at manual feed rate.
0: Disabled
1: Enabled
For details of Accel/decel patterns, see 6-1-5 Axis Movement Operation (Page
248).
Name
Rapid feed S-curve time constant
Setting range
00000000 to 00007530 Hex
00
(0 to 30000)
Explanation
Sets the S-curve filter time constant at rapid feed rate.
For details of Accel/decel patterns, see 6-1-5 Axis Movement Operation (Page
248).
Name
Manual feed S-curve time constant Data
Setting range
00000000 to 00007530 Hex
00
(0 to 30000)
Type
Unit
Data
---
Type
Unit
---
Type
Unit
Data
ms
Type
Unit
ms
Section 4-2
Immediate
updating
No
Initial value
00000000 (0)
Immediate
updating
Yes
Initial value
00000000 (0)
Immediate
updating
Yes
Initial value
00000064 (100)
Immediate
updating
Yes
Initial value
00000064 (100)