Zones
572
■ Enabling and Disabling Zone Bits
Each zone bit can be enabled or disabled by turning ON or OFF the applica-
ble bits for the following variables.
Address
IW0304
IW0305
The following output variables can be used to check whether a zone bit is
enabled or disabled.
Address
Name
OW0304
Zone monitoring
status bits (No. 1 to
16)
OW0305
Zone monitoring
status bits (No. 17 to
32)
Name
Zone enable bits (No. 1 to 16) Enables or disables zone bits
Zone enable bits (No. 17 to
32)
Used to output the enabled/disabled status of
zone bits No. 1 to 16.
No. 1 corresponds to bit 0, and No. 16 corre-
sponds to bit 15.
0: The setting for the zone upper and lower lim-
its is incorrect, or the zone enable bit is OFF
(disabled).
1: The setting for the zone upper and lower lim-
its is correct and the zone enable bit is ON
(enabled).
Used to output the enabled/disabled status of
zone bits No. 17 to 32.
No. 17 corresponds to bit 0, and No. 32 corre-
sponds to bit 15.
0: The setting for the zone upper and lower lim-
its is incorrect, or the zone enable bit is OFF
(disabled).
1: The setting for the zone upper and lower lim-
its is correct and the zone enable bit is ON
(enabled).
Section 9-7
Contents
No. 1 to 16.
No. 1 corresponds to bit 0,
and No. 16 corresponds to bit
15.
0: Disable (Do not use)
1: Enable (Use)
Enables or disables zone bits
No. 17 to 32.
No. 17 corresponds to bit 0,
and No. 32 corresponds to bit
15.
0: Disable (Do not use)
1: Enable (Use)