Connecting MECHATROLINK Devices
Attaching I/F Unit NS115
OMRON R88D-W****
Communications setting
(1)
(3)
(2)
Set MECHATROLINK communications using SW1and SW2.
Transmission setting
MECHATROLINK communications can be specified using the DIP switches
(SW2). See the table below.
Any change of the settings becomes valid after turning OFF the power once,
then ON again.
SW2
Name
Bit 1
Baud rate
Bit 2
No. of Transmitted bytes
Bit 3
Station address
Bit 4
Reserved
ON
OFF 1 2
3
4
SW2 (Default setting)
(1) Remove the connector cover of
the option connector (CN10) on
W-series Servo Driver.
(2) Attach NS115.
(3) For grounding, connect the
ground wire of NS115 to the part
indicated as "G" on the top
surface of the W-series Servo
Driver.
Setting
Content
OFF
4 Mbps
ON
10 Mbps
OFF
17 bytes
ON
30 bytes
OFF
Refer to Station
address setting
ON
OFF
---
Section 3-5
Default setting
ON (Do not
change.)
ON (Do not
change.)
OFF
OFF