Sample Calculation; Calculation Example 1: 32 Ip Networking Connections To Hipath 3750; Hipath 3700 - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

sysdat.fm
System Data
Dynamic Configuration Rules
2.6.8.1

Sample Calculation

2.6.8.1.1

Calculation Example 1: 32 IP Networking Connections to HiPath 3750,

HiPath 3700

HiPath 3750 or HiPath 3700 are connected to another system via an IP networking path with
32 B channels. Codec G.711 is used with a sample rate of 20 msec without encryption for the
IP networking path. The customer only has TDM workpoint clients.
An HXGM3 board with two PDM1 modules is necessary for this configuration:
2 DSPs per HXGM3 and 2 x 1 DSP per PDM1 = 4 DSPs, together supporting up to 32 chan-
nels.
Correspondingly, the total performance available is 980 points.
Performance requirement
32 gateway channels via LAN interface 1 should be included in the calculation. The setting "En-
hanced B Channels" must be activated for this via the WBM. The Virtual Private Network VPN
and Firewall functions are automatically deactivated when this setting is activated.
The signaling load has to be taken into account when calculating performance.
Available extension
modules
Signaling without
H.235 security (inde-
pendent of the WBM
setting "Enhanced B
Channels")
Payload (additional
feature: "Enhanced B
Channels" enabled
over WBM.)
The specified performance requirement of 474.4 points is below the 980 total performance
points that the HXGM3 board can provide. The configuration is feasible.
Note: The configuration is not feasible for HXGS3 and HXGR3 because the static configuration
rules only permit up to 16 channels per board.
2-34
Function
2 x PDM1
32 x IP networking channel (25 calls per hour)
Voice gateway channel over LAN interface 1:
32 x G.711 (received: 20 msec/sent:
20 msec)
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Resource require-
ment
(credit point)
2 x 10 = 20.0
32 x 3.2 = 102.4
32 x 11.0 = 352.0
Total =
474.4
P31003-H3560-S403-54-7620, 09/05