Important Information
Safety Information
1.4.4

General Information

Connecting lines
All cables and lines leaving a system cabinet must be shielded between the connection
point in the cabinet and, at the very least, the point at which they leave the cabinet.
Use a clip and pressure screw to contact all braided shields to the cabinet outlet. This also
applies to continuously connected service equipment.
Connect all cables to the specified connection points only.
Location of safety equipment
When the installation or maintenance is completed, replace all safety equipment in the correct
location.
Checking tools
Check your tools regularly. Only use intact tools.
Closing the housing cover
After maintenance and testing work has been completed, close all housing covers.
Condensation
Condensation may form if equipment is brought onto the operating premises from a cold envi-
ronment. Wait until the temperature of the equipment has adjusted to the ambient temperature
and is completely dry before starting it up.
Wall mounting
Some walls (such as plasterboard walls) have a reduced load-bearing capacity. Before starting
wall mounting, check the load-bearing capacity of the walls.
Fire protection and EMC requirements
To ensure the legal fire protection and EMC requirements, operate the HiPath systems only
when closed. You may open the system only briefly for assembly and maintenance work.
1-10
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
P31003-H3560-S403-54-7620, 09/05