Boards for HiPath 3000

Peripheral Boards

3.3
Peripheral Boards
Caution
7
The system must be powered down and de-energized before removing or inserting
all boards in the HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 and before
removing or inserting the central boards of the HiPath 3800, HiPath 3750 and Hi-
Path 3700.
Note
The HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 peripheral boards must be firmly
inserted into their slots; otherwise contact problems can cause board failure.
3.3.1

CSAPE

Introduction
In V6.0 or later, the cPCI box CSAPE (Central Shelf Access Point Emergency) can be installed
in the HiPath 3800 basic cabinet. The cPCI box contains two fan drawers, the AC power supply
unit ACPCI (part number S30124-X5166-X), and two slide-in shelves for the Embedded Appli-
cation Server EAS.
CSAPE is required when using HiPath All-in-One applications. Information about the supported
applications can be found in the HiPath All-in-One product documentation.
Installation of the cPCI box CSAPE in the system is a purely mechanical operation. There is no
electrical connection between the system and the cPCI box CSAPE All communication be-
tween HiPath 3800 and HiPath All-in-One takes place over the IP network.
3-90
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
P31003-H3560-S403-54-7620, 09/05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents