3.2.4
CBSAP
Introduction
The CBSAP board (Central Board Synergy Access Platform) performs all central control and
switching functions for HiPath 3800 (see Figure 3-4).
Subboards
The following subboards can be used depending on the application:
CMS
clock module (optional)
●
MMC
multimedia card
●
IMODN
integrated modem card new (optional)
●
LIMS
LAN interface module (optional)
●
Contains two Ethernet (10BaseT) LAN connectors (8-pin RJ45 jacks):
–
LAN1 (administration via HiPath 3000 Manager E and CTI functions)
–
LAN2 (not assigned)
MPPI
music on hold (optional)
●
V.24 interfaces (9-pin SUB-D plug)
Service (X50) = for
●
Application (X51) = for connecting a printer or application
●
Switches and indicators
Reset/reload switch:
●
–
Switch pressed < 5 s = Reset activated
–
Switch pressed > 5 s = Reload activated (Fail LED (red) out indicates that a reload is
in progress).
Two LEDs indicating the board status:
●
–
Run (green) = signals the current status of the CBSAP board (see Table 12-2)
–
Fail (red) = error encountered
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
connecting the service PC
boards.fm
Boards for HiPath 3000
Central Boards