Troubleshooting
When blank or incomplete prints persist even after you have checked the above,
perform the following procedure.
A A A A
Unlock the lever and pull out the drum unit.
Reference
For details about how to remove the drum unit, see p.66 "Changing the
5
Color Drum Unit".
B B B B
Remove any paper wrapped around the drum.
C C C C
Remove the master from the drum.
Note
❒ If you still cannot remove the master, release the lock lever at the back of
the drum unit to open the clamp while pulling the master out.
114
ZFRH370E
ZFRH440E