Software Version and Management Module Requirement
Table 2.1 indicates the software and management modules required to support the J4856A and J4894A mini-
GBIC modules (which do not include management).
Table 2.1: Management Module Support for Mini-GBIC Modules Without Management
Management for the (Standard) J4856A Mini-GBIC Module
9300 Models: 9304M or 9308M
Wi
thout Redundant Management
(MI Modu es)
l
Software: Release 06.6.32 or
Greater 06.x Release
J4141A 10 100 Management Module* J4857A M ni-GBIC Redundant
/
J4144A G gabit SX Management
i
Module*
J4146A 4LX/4SX Management
Module*
*Products no longer available from Hewlett-Packard.
Installing or Removing a Mini-GBIC
To install a mini-GBIC:
1. Put on an electrostatic discharge (ESD) wrist strap and attach the copper tape to a metal surface (such as an
equipment rack) to act as ground.
2. If you have not already done so, install a J4856A HP Procurve 9300 Mini-GBIC Module or a J4857A HP
Procurve 9300 Mini-GBIC Redundant Management Module in your routing switch. (Ensure that your routing
switch is running a software version that supports the mini-GBIC module. Refer to "Software Version and
Management Module Requirement" on page 2-7.)
3. Remove the mini-GBIC from its protective packaging.
4. Gently insert the mini-GBIC into the slot on the front panel of the module until the mini-GBIC clicks into place.
The mini-GBICs are keyed to prevent incorrect insertion. A tab on the bottom of the mini-GBIC locks the mini-
GBIC to the front panel of the module.
5. Remove the protective covering from the port connectors and store the covering for future use.
6. Insert the interface cable.
To remove a mini-GBIC:
1. Put on an ESD wrist strap and attach the copper tape to a metal surface (such as an equipment rack) to act
as ground.
2. Disconnect the interface cable from the mini-GBIC.
3. Insert the protective covering into the port connectors.
4. Do one of the following:
9300 Models: 9304M or 9308M W th
Standard Redundant Management
(MII or MIV Modules)
Software: Release 07.1.19 or
Greater
i
Management Module
J4879A T-Flow Redundant
Management Module
J4845A G gLX Redundant
i
Management Module*
J4846A G gSX Redundant
i
Management Module*
J4847A Redundant Management
Module (0-port)*
Management for the (EP)
J4894A Mini-GBIC Module
i
9300 Models: 9304M, 9308M, or
9315M W th EP Redundant
i
Management
Software:
Rel
ease 07.6.00 or
Greater
J4885A M ni-GBIC Redundant
i
Management Module
Installation
2 - 7