HP ProCurve 9304M Installation And Configuration Manual page 101

Routing switches
Hide thumbs Also See for ProCurve 9304M:
Table of Contents

Advertisement

Status LEDs
You can determine the status of a T-Flow processor by observing its LEDs. The processors have the following
LEDs. Each TSP has its own column of TxAct and RxAct LEDs. The left column shows activity for TSP 1, the
middle column shows activity for TSP 2, and the right column shows activity for TSP 3.
LED
Active
Upper LED to
the left of the
serial interface
Power
Lower LED to
the left of the
serial interface
TxAct
Upper LED near
the middle of
the module
RxAct
Lower LED near
the middle of
the module
Software
You can display status information for a T-Flow using either of the following methods.
NOTE:
Slots in a four-slot chassis are numbered 1 – 4, from top to bottom.
Slots in an eight-slot chassis are numbered 1 – 8, from left to right.
Slots in a fifteen-slot chassis are numbered 1 – 15, from left to right.
USING THE CLI
To display the status of a T-Flow using the CLI, enter the following command at any CLI level:
HP9300(config)# show module
Module
S1:
S2: Configured as
S3: 24 Port Switch Module
S4: 24 Port Switch Module
S5:
S6:
Management Module
S7:
S8:
Syntax: show module
The Status column shows the module status. A T-Flow can have one of the following statuses:
ACTIVE – The module is currently the active management module.
Table 4.4: T-Flow LEDs
Position
State
On
Off
On
Off
Blinking
Blinking
Status
Management Module
OK
OK
ACTIV
Using the T-Flow Redundant Management Module
The MP is active.
The MP is not active.
The power status is good.
The power status is not good.
The TSP is transmitting data.
The TSP is receiving data.
Ports Starting MAC
24
00e0.52c2.9f40
24
00e0.52c2.9f60
0
Meaning
4 - 13

Advertisement

Table of Contents
loading