Avaya DEFINITY Server CSI Maintenance Manual page 1774

Table of Contents

Advertisement

Maintenance Objects
If the error occurs three times within 10 minutes, the board is isolated from
the Packet Bus and the board alarmed. To clear the alarm and restore the
board to the Packet Bus, use the commands busyout board UUCSS,
reset board UUCSS, test board UUCSS long, release board UUCSS.
If the problem persists, and there are no PKT-BUS alarms or port alarms,
then replace the circuit pack.
u. Error Type 1538 — The hyperactive circuit pack is out-of-service and may
exhibit one or more of the following symptoms:
The circuit pack is isolated from the system and all trunks or ports on this
circuit pack are placed into the out-of-service state. The system will try to
restore the circuit pack within 20-30 minutes. When no faults are detected
for 20-30 minutes, the UDS1 Interface circuit pack is restored to normal
operation. All trunks or ports of the UDS1 Interface circuit pack are then
returned to the in-service state.
If the board is not restored to normal operation, or the error recurs after the
board was restored to normal operation, escalate the problem.
v. Error Types 3073 to 3160 — For later releases of G3V4 and beyond, only
Error Type 3073 shows that this board is receiving slips and the AUX data
shows the last slip count reported.
w. Error Type 3330 — LAN Critical Error. A critical failure has been detected
in the Packet Bus interface of the circuit pack. This failure may be due to an
on-board fault or a Packet Bus fault. If the Packet Bus is alarmed, refer to
the PKT-BUS Maintenance documentation for recommended repair
procedures.
This error isolates the board from the Packet Bus and raises an alarm. If
the Packet Bus is not alarmed, enter the commands busyout board
UUCSS, reset board UUCSS, test board UUCSS, release board
UUCSS. This should clear the alarm and restore the board to the Packet
Bus.
If the problem persists, and there are no PKT-BUS alarms, then replace the
circuit pack.
x. Error Types 3585 to 3601 — For later releases of G3V4 and beyond, only
Error Type 3585 shows that this board is receiving misframes, and the AUX
Data shows the last misframe count reported.
1774
Issue 5 October 2002
The common circuit pack level tests such as Test #50 and/or Test
#52 abort with error code 2000
The tests run on the ports of this circuit pack return a NO-BOARD
result
A busyout/release of the circuit pack has no affect on test results
A list configuration command shows that the circuit pack and ports
are properly installed