Novell GROUPWISE 8 - ADMINISTRATION Administration Manual page 691

Hide thumbs Also See for GROUPWISE 8 - ADMINISTRATION:
Table of Contents

Advertisement

By default, when using mapped or UNC links, the MTA scans its high priority queues every 5
seconds and its regular and low priority queues every 15 seconds. You can adjust the scan cycle
settings to meet the needs of your GroupWise
®
1 In ConsoleOne
, browse to and right-click the MTA object, then click Properties.
2 Click GroupWise > Agent Settings to display the Agent Settings page.
3 Decrease the number of seconds in the Scan Cycle field if you want the MTA to scan the
regular and low priority queues (2-7) more often.
or
Increase the number of seconds in Scan Cycle field if you want the MTA to scan the regular
and low priority queues (2-7) less often.
4 Decrease the number of seconds in the Scan High field if you want the MTA to scan the high
priority queues (0-1) more often.
or
Increase the number of seconds in the Scan High field if you want the MTA to scan high
priority queues (0-1) less often.
For the locations and specific uses of the MTA input queues, see
Directories" in
GroupWise 8 Troubleshooting 3: Message Flow and Directory
5 Click OK to save the new scan cycle settings.
ConsoleOne then notifies the MTA to restart so the new settings can be put into effect.
Corresponding Startup Switches You can also use the
startup file to adjust the MTA scan cycle.
MTA Web Console You can check the current MTA scan cycle on the
the Performance Settings heading.
®
system.
"Message Transfer/Storage
/cylo
and
/cyhi
Structure.
switches in the MTA
Configuration
page under
Optimizing the MTA 691