7.2
Removal of the cold mirror assembly
The cold mirror cannot be replaced separately. Always replace the whole assembly (mirror + heat sink + fan).
Necessary tools
•
3 mm Allen wrench
•
Nut driver 7 mm
How to remove the cold mirror assembly
1. Remove cover plate of the sealed compartment. See "Open the sealed compartment", page 85.
2. Remove the cover of the Start Pulse Generator as illustrated. This cover is secured with 5 hexagon socket head cap screws.
Use a 3 mm Allen wrench.
Image 7-2
Remove SPG cover
3. Disconnect the fan wire (reference 1).
Tip:
Pull out the top filter for easy access to the fan wire connection.
1
Image 7-3
Electrical disconnection
4. Turn out the 2 hexagon socket head cap screws at the right side (reference 2).
R5905043 DP2K-12C/11CX 19/02/2018
7. Cold mirror assembly
125