1
Image 4-25
Lamp temperature sensor connection
Code 5315: "lamp - temperature sensor short " (Error)
Situation
Damaged insulation of the wire unit
of the temperature sensor (reference
1 & 2image 4-25), which measures
the temperature in the channel of the
air outlet of the Lamp House. When
disconnecting the wire unit of the
temperature sensor from the Signal
Backplane (reference 3 image 4-25)
the error code is changed to "lamp -
temperature sensor open".
Defect temperature sensor
(reference 1 image 4-25), which
measures the temperature in the
channel of the air outlet of the Lamp
House. When disconnecting the wire
unit of the temperature sensor from
the Signal Backplane (reference 3
image 4-25 the error code is changed
to "lamp - temperature sensor open".
Code 5320: "fcb - force lps/lamp off " (Error)
Situation
The Fan Control & Motor board
forces to switch off the Lamp Power
Supply due to an Error.
Malfunction Fan Control & Motor
board.
R5905043 DP2K-12C/11CX 19/02/2018
2
Solution
1.
Repair the insulation of the wire unit using shrink sleeve.
2.
If not repairable, replace the whole wire unit and temperature sensor.
Replace the temperature sensor.
Solution
Look for other errors in the log files and try to solve them.
This can be due to:
•
Overtemperature
•
Lamp house not connected.
•
Light processor is not connected.
Replace the Fan Control & Motor board. See "Removing a board in the card cage",
page 213.
4. Troubleshooting
3
47