Error
Link decryptor - 1.20V supply out of
range
Link decryptor - 1.80V supply out of
range
Link decryptor - 2.50V supply out of
range
Link decryptor - 3.30V regulator out
of range
Link decryptor - Security tamper
Link decryptor - Top side security
enclosure open
Link decryptor - Bottom side security
enclosure open
Link decryptor - Software command
Zeroization
Link decryptor - Physical marriage
tamper
Link decryptor - Logical marriage
tamper
Link decryptor - Service door tamper
Link decryptor - Service log error
Link decryptor - Security battery low
warning
Link decryptor - Security log warning
Code 5832: "ti-link-decryptor - security tamper event" (Error)
Situation
The link decryptor has been
tampered.
R5905043 DP2K-12C/11CX 19/02/2018
Solution
Replace SMPS. See "Replacement of the Switched Mode Power Supply", page 281.
Replace Signal backplane. See "Replacement of the signal back plane", page 231.
Replace link decryptor. See "Replacement of the Link Decryptor", page 243.
Replace SMPS. See "Replacement of the Switched Mode Power Supply", page 281.
Replace Signal backplane. See "Replacement of the signal back plane", page 231.
Replace link decryptor. See "Replacement of the Link Decryptor", page 243.
Replace SMPS. See "Replacement of the Switched Mode Power Supply", page 281.
Replace Signal backplane. See "Replacement of the signal back plane", page 231.
Replace link decryptor. See "Replacement of the Link Decryptor", page 243.
Replace SMPS. See "Replacement of the Switched Mode Power Supply", page 281.
Replace Signal backplane. See "Replacement of the signal back plane", page 231.
Replace link decryptor. See "Replacement of the Link Decryptor", page 243.
The link decryptor has been tampered. Replace link decryptor. See "Replacement of
the Link Decryptor", page 243.
The top side enclosure has been tampered. Replace link decryptor. See "Replacement
of the Link Decryptor", page 243.
The bottom side enclosure has been tampered. Replace link decryptor. See
"Replacement of the Link Decryptor", page 243.
Replace link decryptor. See "Replacement of the Link Decryptor", page 243.
The ICP and/or link decryptor have been removed and inserted again. You need to
remarry both. Start the clear security warning procedure. See "Authorization to clear
security warning on the projector", page 245.
The ICP and link decryptor are not a couple. This means one of both has been replaced.
You need to marry both. Start the clear security warning procedure. See "Authorization
to clear security warning on the projector", page 245.
The Card Cage cover has been removed. Clear the security warning. See "Authorization
to clear security warning on the projector", page 245.
The cover plate of the Light Processor compartment has been removed. Clear the
security warning. See "Authorization to clear security warning on the projector", page
245.
Defect security switches. If all compartments and devices are installed and security error
will not authorize, replace DCI security switches.
Malfunction Signal Backplane. If switch replacement is not the solution, then replace
Signal Backplane. See "Replacement of the signal back plane", page 231.
The Security Log Error indicates that there is no more room to write log entries in the link
decryptor log file.
When this error is active, the DCI compliant Server needs to extract the log data (via
ASM/TLS session) from the link decryptor Security Log. Reads of the security log by any
other entity/means will not impact this error. This error will remain active until the Server
reads enough log entries to create room for 512 log entries. This can take some time.
Playback will be prohibited (black image) as long as this error is active.
The battery of the link-decryptor is low. Leave the projector on for some time to recharge
the battery.
The security log warning indicates that there are less than 512 log entry locations
available in the link decryptor log before the log is full. The attached server needs to
read the log which will clear the log of the projector.
When this warning is active, the DCI compliant server needs to extract the log data (via
ASM/TLS session) from the link decryptor Security Log. This can take some time. Reads
of the security log by any other entity/means will not impact this warning.
Solution
Replace link decryptor. See "Replacement of the Link Decryptor", page 243.