Barco DP2K-12C Service Manual page 65

Hide thumbs Also See for DP2K-12C:
Table of Contents

Advertisement

Situation
Blocked blade of the Dowser
Damaged wire unit of the Dowser
Malfunction motor of the Dowser unit
Malfunction Fan Control board
1
Image 4-36
Dowser connection
Code 5800: "ti-icp - system status = fail" (Error)
This is a generic TI error. Use the Communicator to make a detailed analysis. Go to Diagnostics > Actual > Cinema Front End
Status > Detailed status > Error Messages. Possible error messages are:
Situation
ICP self test - ICP frame memory
test failed
ICP self test - ICP data path
signature test failed
ICP Normal Configuration Error
ICP Boot Configuration Error
FMT Normal Configuration Error
FMT Boot Configuration Error
FMT Satellite Configuration Error
1.20V Supply out of range
1.80V Supply out of range
2.50V Supply out of range
3.30V Supply out of range
ICP FPGA Temperature out of range
ICP FMT FPGA Temperature out of
range
ICP Flash Update Error
R5905043 DP2K-12C/11CX 19/02/2018
Solution
Check if noting is blocking the blade of the Dowser. Do NOT force the blade from the
open position to the closed position or vice versa.
Try to repair the damaged wire unit. If not possible replace the Dowser unit. See
"Replacement of the dowser (shutter)", page 152.
Replace the Dowser unit. See "Replacement of the dowser (shutter)", page 152.
Replace the Fan Control board. See "Removing a board in the card cage", page 213.
Solution
Replace the ICP board. See "Removing a board in the card cage", page 213.
Check the connections to the formatters.
Replace the ICP board. See "Removing a board in the card cage", page 213.
Replace the ICP board. See "Removing a board in the card cage", page 213.
Replace the ICP board. See "Removing a board in the card cage", page 213.
Replace the ICP board. See "Removing a board in the card cage", page 213.
Replace the ICP board. See "Removing a board in the card cage", page 213.
Replace the ICP board. See "Removing a board in the card cage", page 213.
Replace the ICP board. See "Removing a board in the card cage", page 213.
Replace the ICP board. See "Removing a board in the card cage", page 213
Replace the ICP board. See "Removing a board in the card cage", page 213
Replace the ICP board. See "Removing a board in the card cage", page 213
Temperature on ICP is too high. Current active fans have errors. Solve the fan problem
first.
For a correct airflow, check if all covers are closed.
Ambient temperature is too high. Reduce the ambient temperature.
Temperature on ICP is too high. Current active fans have errors. Solve the fan problem
first.
For a correct airflow, check if all covers are closed.
Ambient temperature is too high. Reduce the ambient temperature.
Replace the ICP board. See "Removing a board in the card cage", page 213.
4. Troubleshooting