Barco DP2K-12C Service Manual page 297

Hide thumbs Also See for DP2K-12C:
Table of Contents

Advertisement

Orange
Green
LVPS OK
PFC OK
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
OFF
Normal conditions of diagnostic LEDs when a lamp is switched ON
LED 1 (Yellow right) : flashing (beating as a heart)
LED 2 (Yellow center) : not defined
LED 3 (Yellow left) : flashing few times / second
ERR : OFF
PFC OK : ON (green)
LPS OK : ON (green)
LAMP ON : ON (green)
LVPS OK : ON (yellow/orange)
R5905043 DP2K-12C/11CX 19/02/2018
Green
Green
LPS OK
LAMP OK
ERR
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
Flashing
Flashing
18. Lamp power supply (single module)
Red
Diagnostic
OFF
No input voltage.
OFF
Standby modus of LPS unit.
OFF
PFC and LPS seems to work
normally but the lamp is not
ignited. This situation can be
the result of a bad lamp or
SPG module.
OFF
LPS unit is operating normally.
Projector lamp is ignited.
ON
LPS internal temperature is
too high.
Error detected inside this LPS
fast
unit. In case the other LPS
unit operates normally the
LPS module as a whole works
at 50%.
External error detected from
slow
Fan Control board.
Action
Switch on the projector.
Install another xenon
lamp in case the voltage
on the "LAMP OUT" pins
is 140 volt and you hear
the SPG three times
clicking to ignite the
lamp.
Replace the SPG module
in case the voltage value
on the "LAMP OUT" pins
is >140 volt and you
do not hear the SPG
module clicking to ignite
the lamp.
Replace the LPS module
in case the voltage value
on the "LAMP OUT" pins
is below 140 volt and the
lamp is not ignited.
Check if the LPS air inlet
at the bottom side of the
projector is not blocked.
Check if the air outlet at
the rear of the projector
is not blocked.
If the problem remains,
replace the whole LPS
module.
Replace the LPS module.
Replace Fan Control board.
293

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp2k-11cx

Table of Contents