18. Lamp power supply (single module)
Image 18-14
Fixation frame
5. Secure the 4 spring screws (1).
1
Image 18-15
Fixation screws
6. Connect the grounding wire (PE wire) mounted on the LPS fixation into the socket of the LPS unit (2).
7. Connect the mains input cables with the MAINS INPUT sockets of each LPS module as illustrated (3).
8. Connect the power cables coming from the SPG module with the LAMP OUT sockets of the LPS module as illustrated. Fasten
the nuts with a torque of 4Nm (2.95 lbf*ft).
Warning:
Make sure to place the washers and cable eyes in correct order upon the pin as illustrated. Always use a plain
washer between the output pin and the cable eyes.
Image 18-16
Lamp out connection
P
LPS output pin.
W
Plain washer.
L
Lock washer.
300
3
1
2
W
P
E1
R5905043 DP2K-12C/11CX 19/02/2018
W
L
N