18. Lamp power supply (single module)
18.2 Removal of the LPS module
Necessary tools
•
Flat screw driver
•
Nut driver 10 mm
How to remove
1. Remove the CTLB IN (1) connection.
Image 18-2
Communication connection
2. Disconnect the MAINS INPUT cables (3).
1
Image 18-3
Remove LPS
3. Disconnect the grounding wire (PE wires) (2, image 18-2).
4. Disconnect both LAMP OUT power cables. Use a 10 mm nut driver.
Caution:
Do not loose the washers which fit between the fixation nuts and the cable eye.
5. Release the 4 captive screws (1, image 18-2) and take off the fixation frame.
6. Slide out the LPS module.
294
1
3
1
2
R5905043 DP2K-12C/11CX 19/02/2018