8.12 Replacement of the Light Sensor Module
Purpose of the Light Sensor in the Light Pipe
To obtain a Constant Light Output (CLO) from the projector a light sensor is mounted just behind the fold mirror. On a regular base
the controller of the projector read the measured values of this light sensor and, if required, sends corrective information to the Lamp
Power Supply (LPS).
The left cover has to be removed from the projector to replace the Light Sensor Module. This procedure as-
sumes that the left cover is already removed from the projector.
Necessary tools
•
TX10 Torx screw driver.
•
Light meter.
How to replace the Light Sensor Module of the Light Processor
1. Disconnect the wire unit from the Light Sensor Module.
Image 8-17
Light sensor connection
2. Remove the Light Sensor Module by releasing the two Torx screws (reference 1). Use a TX10 Torx screw driver.
1
Image 8-18
Light sensor unit removal
3. Install a new Light Sensor Module. Use a TX10 Torx screw driver to fasten both screws (reference 1).
4. Reconnect the wire unit with Light Info Module (image 8-17).
5. Place a light meter in the center of the screen and calibrate the Light Sensor Module. For detailed instructions see user guide of
the Communicator software.
R5905043 DP2K-12C/11CX 19/02/2018
8. Light processor assembly
151