Code 5345: "dmd red - temperature sensor short" (Error)
Situation
Damaged wire unit of the
temperature sensors (reference
1 image 4-24) which measures the
temperature of the DMD of the red
channel.
Defect temperature sensor which
measures the temperature of the red
channel.
Code 5351: "smps primary heatsink - temperature high" (Warning)
Situation
Ambient temperature too high.
Blocked front filter.
Malfunction SMPS module
Malfunction Fan Control board.
Code 5361: "smps secondary heatsink - temperature high" (Warning)
Situation
Ambient temperature too high.
Blocked front filter.
Malfunction SMPS module
Malfunction Fan Control board.
Code 5364: "smps secondary heatsink - temperature sensor open " (Error)
Situation
Malfunction SMPS module
Code 5365: "smps secondary heatsink - temperature sensor short" (Error)
Situation
Malfunction SMPS module
Code 5371: "dmd red fan - voltage high" (Warning)
Situation
Malfunction Fan & Motor Control
board.
Code 5372: "dmd red fan - voltage too low" (Error)
Situation
Malfunction SMPS module. All other
fans also report voltage low error.
Damaged insulation of the wire unit
of the DMD red fan.
Malfunction Fan & Motor Control
board.
Malfunction signal backplane
R5905043 DP2K-12C/11CX 19/02/2018
Solution
1.
Repair the wire unit.
2.
If not repairable, replace the whole Light Processor Unit. Contact Barco for further
instructions to repair the malfunction Light Processor Unit.
Replace the whole Light Processor Unit. Contact Barco for further instructions to repair
the malfunction Light Processor Unit. It is too critical to replace this temperature sensor
in the field. The replacement of this temperature sensor must be done at factory or
at an authorized service center.
Solution
Check the ambient temperature at the air inlets of the projector. Make sure that the
ambient temperature does not exceed 35°C (95°F).
Clean the filter at the front side of the projector or replace with a new one. See
"Removing the front dust filter", page 333.
Replace the SMPS module.
Replace the Fan Control board. See "Removing a board in the card cage", page 213.
Solution
Check the ambient temperature at the air inlets of the projector. Make sure that the
ambient temperature does not exceed 35°C (95°F).
Clean the filter at the front side of the projector or replace with a new one. See
"Removing the front dust filter", page 333.
Replace the SMPS module.
Replace the Fan Control board. See "Removing a board in the card cage", page 213.
Solution
Replace the SMPS module. See "Replacement of the Switched Mode Power Supply",
page 281.
Solution
Replace the SMPS module. See "Replacement of the Switched Mode Power Supply",
page 281.
Solution
Replace the Fan & Motor Control board. See "Removing a board in the card cage",
page 213
Solution
Replace the SMPS module. See "Replacement of the Switched Mode Power Supply",
page 281
Remove the Light Processor from the projector and check the insulation of the wire
unit of the fan.
1.
Repair the insulation of the wire unit using shrink sleeve.
2.
If not repairable, replace the whole wire unit and fan.
Replace the Fan & Motor Control board. See "Removing a board in the card cage",
page 213