Note:
After writing data to PCSR, always write to PDUT.
Note:
When the external TRG input is selected as the start trigger, input a pulse with the minimum or lager
pulse width shown below.
Minimum pulse width: 2 machine cycles
However, a pulse with a smaller width may still be recognized as a valid pulse. Also, since this
product has no filter for the external TRG input, add a filter, if necessary.
13.4.2 One-shot Operation
At one-shot operation, a single pulse of any width can be output by a trigger. With restart enabled, the
counter is reloaded when the start trigger is detected during operation.
n When restart disabled
Start trigger
m
n
o
PPG
n When restart enabled
Start trigger
m
n
o
PPG
Rising edge detected
(2)
Fig. 13.4 Timing of Disabling One-shot Operation Restart
Rising edge detected
Fig. 13.5 Timing of Enabling One-shot Operation Restart
PPG TIMER
Trigger ignored
(1)
Restart by trigger
(1)
(2)
13-11