RAID operations
At this point, the RAID is split, and the drive marked FAILED is the backup drive and will no
longer be written to. A release upgrade or PEP installation can now be completed without
impact to the →backup' drive.
Figure 25: MegaRAID Power Console Plus drive status
Perform a CallPilot software upgrade
Let the system boot. The system will still run after Channel 2 of the RAID card was taken out
of service and will boot to Windows. Perform the software upgrade.
To synchronize the RAID after a successful upgrade
To restore RAID to full service after completing a successful upgrade or update:
1. WITHOUT shutting down the server, from Windows, click Start → Programs →
2. Click OK.
3. In the Physical Devices section, right-click the Channel 2 hard disk drive that was
134
Avaya CallPilot® 703t Server Maintenance and Diagnostics
Power Console Plus → Launch Client.
Note:
Ensure that Access Mode → Full Access is selected.
Result: The MegaRAID Power Console Plus window appears.
marked FAILED.
December 2010