4. Install the new hard drive in the drive carrier as described in
5. Install the drive carrier assembly in the server as described in
Hard drive description
The server is equipped with two 36 Gbyte wide SCSI hard drives, each one inch high. The last
bay must remain empty to ensure proper system cooling.
Caution:
Risk of equipment damage
The internal SCSI interface in this system supports only single-ended SCSI devices. Use
Avaya authorized drives only.
SCSI drive cabling
The hard drive assembly package includes a standard 68-pin, 68 conductor, twisted-pair wide
(16-bit) SCSI ribbon cable, with terminator. This cable has three connectors: the first is for the
terminator, the second is for the hard drive, and the third is for connection to the RAID card.
Hard drive configuration
Ensure that the hard drives are configured as follows (for instructions, refer to the original
equipment manufacturer documentation):
• termination power: Set the hard drive on each SCSI bus to provide termination power to
the bus.
• term power jumper: enabled
• parity checking (if this setting is available): enabled on both drives
• all other settings: factory default
Avaya CallPilot® 703t Server Maintenance and Diagnostics
drive
on page 111.
Hard drive description
7
on page 110.
To install the hard
December 2010
107