Avaya CallPilot 703t Maintenance And Diagnostics page 145

Hide thumbs Also See for CallPilot 703t:
Table of Contents

Advertisement

2. Remove the faulty MPB96 board from its slot, and save the retaining screw.
3. Unpack the replacement MPB96 board.
4. Hold the MPB96 board by its top edge or upper corners, and then align it with the
5. Press the new MPB96 board firmly into its slot.
6. Secure the board using the retaining screw that you removed earlier.
7. Replace the upper fan holder foam.
8. Replace the server cover.
9. Reconnect the peripheral device and power cables.
10. Reconnect the DS30X cable to the faceplate of the MPB96 board.
11. Power up the server and log on to Windows.
Avaya CallPilot® 703t Server Maintenance and Diagnostics
• DS30X cable(s) (Meridian 1 and Communication Server 1000 only)
b. Place the server on its side.
c. Remove the side cover.
d. Remove the upper fan holder foam.
For instructions, see
Preparing the server for hardware maintenance
Warning:
Risk of personal injury or equipment damage
Failure to follow the procedures in
maintenance
on page 85 can result in electrical shock or equipment damage.
following:
• end-plate opening in the chassis Ensure that the tapered foot of the board's
retaining bracket fits into the slot in the expansion slot frame.
• PCI connector
For instructions, see
To replace the upper fan holder foam
Note:
Be careful not to pinch any cabling when replacing the server cover.
Note:
Ensure that a single-point ground reference is available for all the power outlets
serving the Avaya CallPilot server and its peripherals. Before the CallPilot server
installation, a qualified electrician must implement the single-point ground
reference requirement between the power outlets of the CallPilot server and the
power outlets of the switch.
To replace an MPB96 board
Preparing the server for hardware
on page 85.
on page 91.
December 2010
145